General Specification
Dimensions and Weight for Console
• Height: 282 mm console only
• Width: 274 mm console only
• Depth: 56 mm console only
• Weight: approx. 3.6 kg (8 lbs.) with probe
Electrical Power for Console and Docking
• Voltage: 100- 240 V AC
• Frequency: 50/60 Hz
• Power: Max. 180 VA
Console Design
• Tablet Style
• Lithium-Ion Battery Pack (standard)
• 1 probe port with SC-connector
• Speaker
• Docking station and docking cart are options
• Stylus
User Interface
Touch Screen
• Simplified layout
• Mode-specific controls
• Alphanumeric Keyboard
• Measurement
• Annotation
• Utility settings
• Patient information entry
• Touch and stylus user interface
Display Screen
• 10.4 inch High-Resolution Color LCD
- Display: 800x600
• 170-degree wide angle view
Hard keys
• 10 Ergonomic Hard Key Operation (backlit)
• On/Off button
LED
• Battery life
System Overview
Packages
• Musculoskeletal
• Vascular Access
• Anesthesia
• Point of Care
• Interventional
Transducer Types
• Linear Array
• Phased Array
• Convex Array
Operating Modes
• B-Mode
• M-Mode
• Color Flow Mode (CFM)
• Power Doppler Imaging (PDI)
Standard Features
• High-resolution 10.4 inch Color LCD
• Standard CINE Memory (120MB)
• Removable secure digital storage (SD)
• Loops storage from memory
• Automatic Optimization
- Auto Tissue Optimization: ATO
• Distance/Area Measurement
Software Features
• Applications
• Color
• M-Mode
• DICOM
Hardware Features
• Battery Pack
• Docking Cart
• Docking Station
• Probes
Media and Peripherals
• USB thermal B&W printer: Sony UPD-897 (option)
• Memory Stick (option)
Display Modes
• B-Mode
• M-Mode
• CFM
• PDI
Display Annotation
• Institution/Hospital Name
• Date: MM/DD/YY and DD/MM/YY
• Time: 24 hours or 12 hours configurable
• Patient Name: Last, First
• Patient Identification: 16 characters
• Power Output Readout
- MI: Mechanical Index
- TIS, TIB, TIC: Thermal Index
• System Status (real-time or frozen)
• Probe Orientation Marker: Coincides with a probe orientation marking on the probe
• Loop replay
• Measurement Results Window
• Probe Type
• Preset Name
• Imaging Parameters by Mode (current mode)
- B-Mode:
Gain
Image Depth
Power Output: Low, Med, High
- M-Mode:
Gain
Image Depth
Power Output: Low, Med, High
- Color Flow Mode:
Color Gain
Image Depth
Power Output: Low, Med, High
• B Scale Markers: Depth
• System Messages Display
• Battery Status
• Biopsy Guide Line and Zone
• Primary Parameter Menu (depends on current mode)
- B-Mode
ATO
- M-Mode
Speed
- Color Flow Mode
Angle Steer
PRF
Invert
- CINE Mode
Previous Frame
Next Frame
Play/Pause
System Parameters
System Setup
Diagnostic Categories: Customer focused (ex. Anesthesiology)
• Factory Default Application Data
• Languages setup for UI: English, German, Fr bench, Italian, Spanish, Portuguese, Simplified Chinese, Swedish, Norwegian, Danish, Finnish, Greek, Russian, Dutch, Japanese
• Languages for Manuals: English, French, Spanish, German, Italian, Portuguese, Japanese, Chinese, Czech, Danish, Dutch, Estonian, Finnish, Greek, Hungarian, Latvian, Lithuanian, Norwegian, Polish, Russian, Slovakian, Swedish, Korean
• Operation Error: Error message display
• Patient Name Format: Last, First
• System Boot Up: < 17 sec
• Probe Loading: < 5 sec
Pre-Processing
• Acoustic Power Output
• Color Flow Mode
- Gain
- Steer
- PRF
Post-Processing
• Auto Tissue Optimize (ATO)
Imaging and Presentation
Software Intensive Ultrasound Imaging Platform
• Digital Beamformer
- Displayed Imaging Depth: Minimum Depth of Field: 1 cm
(Zoom and probe dependent); Maximum Depth of Field: 27 cm
(probe dependent)
• Continuous Dynamic Receive Focus/Aperture
• Multi-Frequency/Wideband Technology
• Image Reverse: Right/Left
CINE Memory/Image Memory
• Standard CINE Memory (120MB)
• CINE Review: Frame-by-frame, Loop replay
Image Archive/Connectivity
• Image Browser: Archived images from past patient appear, as well as images stored for the current patient
- Previewing an Image
• Image Management (removable media)
- Delete Selected Image
- Review in Full Image Area
• One Print (Recording) UI Keys to approved printer
- Archiving Format:
JPEG
MPEG4
• Capture Area:
- Image Area
• Archiving Image Frames:
- Single: stores single frame while in Freeze mode
- Multiple: stores image loops while in Live scan mode
- Patient Information Window, and Search/Create Patient Window
- Column header sorting in Image Review Screen by name, date, ID
- Automatic generation of patient ID
- Search by ID, First Name and Last Name
• DICOM
- DICOM Store
- Worklist Query
• Network Quicksave
Scanning Parameters
B-Mode
• B Acoustic Output: preset in 3 steps, toggle for Low, Med, High
• Thermal Index: TI
• Gain: preset in 3 steps, toggle for Low, Med, High
• Harmonics: defined by the application
• Depth: 1 – 27 cm, preset in 6 or less steps, probe dependent
• Frequency: defined by the application
• Grey Map: defined by the application
M-Mode
• B Acoustic Output: preset in 3 steps, toggle for Low, Med, High
• Thermal Index: TI
• Gain: preset in 3 steps, toggle for Low, Med, High
• Depth: 1 – 27 cm, preset in 4 steps or less, probe dependent
• Speed: 7 steps
• Frequency: defined by the application
Color Flow Mode
• Invert: On/Off
• CF Acoustic Output: preset in 3 steps, toggle for Low, Med, High
• PRF: preset in 3 steps, probe dependent
• Gain: preset in 3 steps, toggle for Low, Med, High
• Steer: preset in 3 steps, toggle for Right, Center, Left
• CF Vertical Size (mm): default preset
• CF Center Depth (mm): default preset
• CF Frequency: defined by the application
• Color Map: preset, defined by the application
PDI-Mode
• PDI Acoustic Output: preset in 3 steps, toggle for Low, Med, High
• PRF: preset in 3 steps, toggle for Low, Med, High, probe dependent
• Gain: preset in 3 steps, toggle for Low, Med, High
• Steer: preset in 3 steps, toggle for Right, Center, Left
• PDI Vertical Size (mm): default preset
• PDI Center Depth (mm): default preset
• PDI Frequency: defined by the application
• Color Map: defined by the application
Measurements and Calculations
• Distance
• Area
• Heart Rate/Time
Probes
• 12L-SC Wide Band Linear Probe
- Applications: Vascular Access, Anesthesia, Point of Care, Interventional and Musculoskeletal
- Number of Elements: 192
- FOV(max): 39mm
- B-Mode Imaging Frequency: 5-13 MHz, factory preset, non-configurable
- CFM Imaging Frequency: 4-6 MHz, factory preset, defined by application
- Steered Angle: +/-20
- Biopsy Guide Available: Multi Angle
• 3S-SC Wide Band Phased Array Probe
- Applications: Cardiac, Abdomen
- Number of Elements: 64
- FOV: 60°-90°, factory preset, non-configurable
- B-Mode Imaging Frequency: 1.7 –4.0 MHz, factory preset, non-configurable
- CFM Imaging Frequency: 1.4-2.5MHz, factory preset, non-configurable
- Biopsy Guide Available: Multi Angle
• 4C-SC Wide Band Convex Probe
- Applications: Abdomen, Musculoskeletal, Thoracic/Pleural
- Number of Elements: 128
- Convex Radius: 60mmR
- FOV: 58°
- B-Mode Imaging Frequency: 2.0-5.5 MHz, factory preset, non-configurable
- CFM Imaging Frequency: 2.5-3.1 MHz, factory preset, non-configurable
- Biopsy Guide Available: Multi Angle
• L8-18i-SC Wide Band Linear Probe
- Applications: Vascular Access, Anesthesia, Point of Care, Interventional and Musculoskeletal
- Number of Elements: 168
- FOV(max): 25.2mm
- B-Mode Imaging Frequency: 8-18 MHz, factory preset, non-configurable
- CFM Imaging Frequency: 6-10 MHz, factory preset, defined by application
- Steered Angle: +/-20
Inputs and Outputs
• Outputs
- DVI-D interface on docking station and docking cart
• Connectors
- USB interface on docking station and docking cart
- Docking Connector
- Removable SD card
- Wireless LAN
- Wired LAN
Safety Conformance
Venue 40 is:
Listed to UL 60601-1 by a Nationally Recognized Test Lab
• Certified to CAN/CSA-C 22.2 No. 601.1 by an SCC accredited Test Lab
• CE Marked to Council Directive 93/42/EEC on Medical Devices
• Conforms to the following standards for safety:
- EN/IEC 60601-1 Electrical medical equipment
- EN/IEC 60601-1-1 Electrical medical equipment
- EN/IEC 60601-1-2 Electromagnetic compatibility
- EN/IEC 60601-1-4 Programmable medical systems
- EN/IEC60601-1-6 General requirements for safety – Collateral Standard: usability
- EN/IEC 61157 Declaration of acoustic output
- EN/IEC60601-2-37 Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment
- ISO 10993 Biological evaluation of medical devices
- AIUM/NEMA UD3 Acoustic output display (MI, TIS, TIB, TIC)
• Compliant with DIRECTIVE 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) requirement.
Not all features or specifications described in this document may be available in all probes and/or modes.